Hi Bryan -
Applied CU2 to our Dev lab. All seems to be going well so far except for my W2K8 64bit terminal server.
Applied CU2 Update via CU2 Hotfix Utility "Server Update" since we have the SCOM console installed. That went well. We also have the SCOM Agent installed. But when I applied the Agent Update per your notes via the HotFix Utility or even when I manually apply KB979257-X64-AGENT.msp, we now receive an alert "Agent and OS architecture are the same" complaining they agent and OS versions don't match.
My TS server has AMD64 bit processor technology. I have verified that the Agent and CU2 patches are indeed the 64 bit versions from the ADM64 directories. With just the agent applied, I do not get the alert, only after CU2 is applied. I have tested/tried this several times to make sure I had the correct items applied. Same results.
Is this normal? Do I need to set any overrides for the new monitor Agent Version/Architecture monitor checks? Any thoughts are greatly appreciated. Thank you.
Regards