Instance Summary 2008 Dashboard crash

Instance Summary 2008 Dashboard crash

  • Comments 5
  • Likes

Hi again!

This is an issue that affects the Instance Summary 2008 dashboard from the SQL MP with SCOM 2012 RTM and SP1 environments regardless of UR.

Basically when the dashboard should load, it crashes the whole SCOM console. Also check the OperationsManager Event Log for following entries:

Application: Microsoft.EnterpriseManagement.Monitoring.Console.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an unhandled exception.
Exception Info: System.Reflection.TargetInvocationException
Stack:
   at System.RuntimeMethodHandle.InvokeMethod(System.Object, System.Object[], System.Signature, Boolean)
   at System.Reflection.RuntimeMethodInfo.UnsafeInvokeInternal(System.Object, System.Object[], System.Object[])
   at System.Delegate.DynamicInvokeImpl(System.Object[])
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.DispatcherOperation.InvokeImpl()
   at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object)
   at System.Windows.Threading.DispatcherOperation.Invoke()
   at System.Windows.Threading.Dispatcher.ProcessQueue()
   at System.Windows.Threading.Dispatcher.WndProcHook(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object)
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32)
   at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr)
   at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef)
   at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef)
   at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame)
   at System.Windows.Application.RunInternal(System.Windows.Window)
   at System.Windows.Application.Run()
   at Microsoft.EnterpriseManagement.ConsoleFramework.ConsoleApplication.LaunchWindow()
   at Microsoft.EnterpriseManagement.Monitoring.Console.Internal.ConsoleApplicationBase.LaunchWindow()
   at Microsoft.EnterpriseManagement.ConsoleFramework.ConsoleApplication.Run()
   at Microsoft.EnterpriseManagement.Monitoring.Console.Internal.Program.Main()
==
Faulting application name: Microsoft.EnterpriseManagement.Monitoring.Console.exe, version: 7.0.9538.1084, time stamp: 0x52420e08
Faulting module name: KERNELBASE.dll, version: 6.1.7601.18409, time stamp: 0x5315a05a
Exception code: 0xe0434352
Fault offset: 0x000000000000940d
Faulting process id: 0x14ac
Faulting application start time: 0x01cf9abb725b7044
Faulting module path: C:\Windows\system32\KERNELBASE.dll
Report Id: d6473442-06af-11e4-839a-0050569a6892
Faulting package full name: %14
Faulting package-relative application ID: %15

If the exceptions match, please upgrade to R2.. in my case the crash stopped occurring.

Apparently there are a lot of compatibility issues which are official for the new dashboards from the SQL MP and non 2012 R2 SCOM environments. So if you have this issue or others with the dashboards.. always be sure you have R2:)

Comments
  • Interesting. I am already on 2012 R2 and get this error.

    Faulting application name: Microsoft.EnterpriseManagement.Monitoring.Console.exe, version: 7.1.10226.0, time stamp: 0x522a58ed
    Faulting module name: KERNELBASE.dll, version: 6.3.9600.17055, time stamp: 0x532954fb
    Exception code: 0xe0434352

  • thank you

  • thank you

  • thank you

  • My 2008 Instance Summary Dashboard is ok but the SQL 2012 one crashes! 14 is ok too...? I've only just upgraded to SP1 in Prod, not keen on immediately upgrading to R2 though!